Using our revolutionary Biochip Array Technology (BAT), the Evidence MultiSTAT is an automated analyser that enables on-site simultaneous detection of up to 21 classical, prescription, and synthetic drugs from a single sample. Designed to work across a variety of matrices, our patented multi-analyte testing platform provides a complete toxicology profile within minutes — changing the landscape of drug detection forever!
With minimal sample preparation required, qualitative results can be provided in under 20 minutes, offering an efficient and accurate toxicology screen.
Testing is available across multiple matrices including; blood, urine, and oral fluid to accommodate any testing requirements.
With prefilled reagent cartridges and a simple interface, non-laboratory trained staff can operate the analyser in any environment and achieve results in minutes.
Using chemiluminescence as a measurement principle, the Evidence MultiSTAT consistently delivers accurate results and offers a highly sensitive way to detect drugs of abuse.
The Evidence MultiSTAT facilitates on-site simultaneous screening of multiple drug classes, including classical, prescription, and synthetic drugs of abuse.
Cat. No. EV4195
Time to Result: 23 minutes
Assay | Cut-off | Assay | Cut-off |
---|---|---|---|
6-MAM | 10 ng/ml | Methadone | 10 ng/ml |
AB-CHMINACA | 5 ng/ml | Methamphetamine | 50 ng/ml |
AB-PINACA | 2 ng/ml | Opiates | 80 ng/ml |
Amphetamine | 50 ng/ml | Oxycodone | 10 ng/ml |
BZG (Cocaine Metabolite) | 25 ng/ml | PCP (Phencyclidine) | 5 ng/ml |
Barbiturates | 50 ng/ml | Pregabalin | 1000 ng/ml |
Benzodiazepines | 20 ng/ml | TCA (Tricyclic Anti-depressants) | 60 ng/ml |
Buprenorphine | 2 ng/ml | THC (Cannabinoids) | 10 ng/ml |
EtG (Ethyl Glucuronide) | 500 ng/ml | Tramadol | 5 ng/ml |
Fentanyl | 1 ng/ml | α-PVP | 5 ng/ml |
Urine I – Cat. No. EV4193
Time to Result: 17 minutes
Assay | Cut-off | Assay | Cut-off |
---|---|---|---|
6-MAM | 10 ng/ml | Methadone | 300ng/ml |
AB-CHMINACA | 10ng/ml | Methamphetamine | 500ng/ml |
AB-PINACA | 3ng/ml | Opiates | 300ng/ml |
BZG (Cocaine Metabolite) | 150 ng/ml | Opiates | 200 ng/ml |
Barbiturates | 200 ng/ml | Oxycodone | 50 ng/ml |
Benzodiazepines I | 150ng/ml | TCA (Tricyclic Anti-depressants) | 150 ng/ml |
Benzodiazepines II | 150ng/ml | THC (Cannabinoids) | 20 ng/ml |
Buprenorphine | 1 ng/ml | Tramadol | 5 ng/ml |
EtG (Ethyl Glucuronide) | 750 ng/ml | α-PVP | 5 ng/ml |
Fentanyl | 2 ng/ml | – | – |
Urine II – Cat. No. EV4292
Time to Result: 17 minutes
Assay | Cut-off | Assay | Cut-off |
---|---|---|---|
6-MAM | 10 ng/ml | Methadone | 300ng/ml |
AB-CHMINACA | 10ng/ml | Methamphetamine | 500ng/ml |
AB-PINACA | 3ng/ml | Opiates | 300ng/ml |
Amphetamine | 500ng/ml | PCP (Phencyclidine) | 25ng/ml |
BZG (Cocaine Metabolite) | 300ng/ml | Pregabalin | 300ng/ml |
Barbiturates | 200ng/ml | TCA (Tricyclic Anti-depressants) | 150ng/ml |
Benzodiazepines | 200ng/ml | THC (Cannabinoids) | 50ng/ml |
Creatinine | 20mg/dl | Tramadol | 20ng/ml |
EtG (Ethyl Glucuronide) | 750 ng/ml | UR-144 (Synthetic Cannabinoids) | 10ng/ml |
Fentanyl | 2 ng/ml | α-PVP | 5ng/ml |
Cat. No. EV4117
Time to Result: 17 minutes
3-fold dilution applied by the collection device has been accounted for in the cut-off material provided.
Assay | Cut-off | Assay | Cut-off |
---|---|---|---|
6-MAM | 2 ng/ml | LSD | 1 ng/ml |
Amphetamine | 50 ng/ml | Methadone | 4 ng/ml |
BZG (Cocaine Metabolite) | 20 ng/ml | Methamphetamine | 50 ng/ml |
Barbiturates | 50 ng/ml | Opiates | 10 ng/ml |
Benzodiazepines I | 10 ng/ml | Oxycodone | 8 ng/ml |
Benzodiazepines II | 10 ng/ml | PCP (Phencyclidine) | 5 ng/ml |
Fentanyl | 1 ng/ml | Tramadol | 4 ng/ml |
JWH-018 (Synthetic Cannabinoids) | 5 ng/ml | UR-144 (Synthetic Cannabinoids) | 10 ng/ml |
Ketamine | 50 ng/ml | α-PVP | 2 ng/ml |
Cat. No. EV4279
Time to Result: 17 minutes
4-fold dilution applied by the collection device has been accounted for in the cut-off material provided.
Assay | Cut-off | Assay | Cut-off |
---|---|---|---|
6-MAM | 3 ng/ml | LSD | 1.5 ng/ml |
Amphetamine | 60 ng/ml | Methadone | 5 ng/ml |
BZG (Cocaine Metabolite) | 30 ng/ml | Methamphetamine | 70 ng/ml |
Barbiturates | 60 ng/ml | Opiates | 15 ng/ml |
Benzodiazepines I | 15 ng/ml | Oxycodone | 10 ng/ml |
Benzodiazepines II | 15 ng/ml | PCP (Phencyclidine) | 7 ng/ml |
Buprenorphine | 1.5 ng/ml | THC (Cannabinoids) | 5 ng/ml |
Fentanyl | 1.5 ng/ml | Tramadol | 5 ng/ml |
JWH-018 (Synthetic Cannabinoids) | 20 ng/ml | UR-144 (Synthetic Cannabinoids) | 25 ng/ml |
Ketamine | 65 ng/ml | α-PVP | 2.5 ng/ml |
Analyser Description | Fully automated Biochip Array analyser |
Dimensions | 585 (H) x 535 (D) x 570 (W) mm |
Weight | 48kg (106lbs) |
Biochip Format | Cartridge-based system — assay reagents sealed in a cartridge |
Connectivity | LIMS uni-directional interface |
Data Back-up Methods | Data export functionality |
Environment | Operating temperature 18 ̊C-32 ̊C, <80% Relative humidity, <2000m Altitude, Pollution: Degree 2 (IEC 664) Stable workbench required |
Measurement Principal | Competitive techniques with chemiluminescent reaction |
Operator Interface | 15.6″ touch screen |
Peripherals | Barcode scanner Printer can be connected (not included) |
Power Requirements | Input Voltage 110-240v |
Sample Loading | Single cartridge loading bay |
Sample Volume | 200μl |
Time to Result | 17 minutes – 23 minutes |